Datasheet: CertiFiber®Pro Optical Loss Test Set | Fluke Networks

Ficha técnica: CertiFiber®Pro Optical Loss Test Set

The CertiFiber® Pro is a Tier 1 (basic) fiber certification solution and part of the Versiv™ Cabling Certification product family. The Versiv line also includes copper certification and OTDR analysis modules. Versiv is designed around the revolutionary ProjX™ management system and Taptive™ user interface. ProjX helps ensure jobs are done correctly the first time, thus reducing rework. With the intuitive Taptive user interface, instrument set-up and operation are so simple, even operators with limited cabling skills can successfully test and troubleshoot a system. Analysis of measurement data and professional test reports are easy with the familiar LinkWare™ PC management software. Upload and consolidate fiber and copper certification test results from remote sites and manage projects from smart devices using the LinkWare Live service.

Versiv makes you money every time you use it.

 Cabling Certification with CertiFiber Pro

Installing a high performance fiber optic cabling system starts with systems design and ends with systems acceptance. Certifying cabling to industry performance standards is a core element of the process. The faster it goes, the more profitable you'll be. Unfortunately, there are a lot of things that slow the process down – setting the tester up incorrectly, testing to the wrong limits, dirty fiber endfaces causing testing failures, waiting for lead technicians to analyze or troubleshoot failures, misinterpretation of results, and test reports that customers can't understand.

The CertiFiber Pro Optical Loss Test Set (OLTS) helps cabling professionals accomplish more than ever. It's all about accurate, error-free certification, making jobs easier to manage and certifying fiber optic cabling to industry standards, faster. CertiFiber Pro OLTS complies with all applicable cabling standards, which call out the new Encircled Flux launch condition requirements for optical sources. It's not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.

Unique features:

  • Versiv enables users to accomplish more than ever with a cable tester, accelerating every step of the testing process
  • ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  • LinkWare PC management software provides unmatched analysis of test results and professional test reports
  • LinkWare Live allows you to manage results and the testing process from your smart devices

Performance:

  • Three-second Autotest optical loss measurement of two fibers at two wavelengths with distance measurement and optical loss budget calculation
  • Provides automatic Pass/Fail analysis to industry standards or custom test limits
  • Identifies incorrect test procedures resulting in negative loss readings
  • Double ended Pass/Fail certification of fiber optic connector endfaces
  • Graphical indication of problem areas on fiber endfaces due to contamination, pits, chips and scratches
  • Interchangeable power meter adapters available for all typical connector types (SC, ST, LC and FC) to enable the most accurate 1-jumper reference method
  • Built-in visual fault locator for basic troubleshooting and polarity determination
  • Dual wavelength measurement capability on a single fiber allows the tester to be used in applications that require only one fiber link
  • Compliant with TIA-526-14-B and IEC 61280-4-1 Encircled Flux requirements with no additional equipment or procedures
  • Integrated Wi-Fi allows you to easily upload results to LinkWare Live
Pro Optical Loss Test  Set

Standards:

  • Allows combined OLTS Tier 1 (basic), OTDR Tier 2 (extended) certification, end-face inspection and reporting when paired with OptiFiber™ Pro OTDR
  • Set reference wizard verifies test reference cords (TRCs) per ISO/IEC 14763-3 and eliminates negative loss errors
  • Encircled Flux compliant optical launch conditions as required by ANSI/TIA and ISO/IEC standards for testing multimode fiber
  • Certify fiber optic endfaces to industry standards – IEC 61300-3-35

Detailed View of Fiber Loss Results

View the results of each fiber tested at the same time and the Pass/Fail status on the test results screen. Easily identify the fiber type, test limits, loss and which fiber correlates to each result. All good results are highlighted with a green icon, any faulty events are highlighted with red icons and fibers are identified as output or input to facilitate quick identification and corrective action. The Taptive user interface also makes the results screen a powerful tool with a detailed window which can be touched to drill down and see detailed results.

The screen below shows margin and limit values in the window. Simply tap the screen to drill into specific results as shown in second image.

Loss Test Result Data in CertiFiber Pro

Complete data is displayed with a test result. The dotted line shows what's included in the measurement. Detail windows show the results for each fiber tested.

Fiber Margin and Allowable Limits

Detail shows margin and allowable limits for the fiber at two wavelengths.

Double Ended Fiber Optic Endface Certification

Fiber optic connector end-face contamination is a leading cause of fiber failures. Dirt and contaminants cause insertion loss and back-reflection that inhibit optical transmission and causes havoc with transceivers. Fiber loss testing can expose this problem, but in many cases, dirty connections make fiber testing time consuming and inaccurate. Since dirt can be an issue before, during, or after fiber optic certification testing, and migrate from one fiber optic connector end-face to another upon mating, both sides of any connection must always be cleaned and inspected.

CertiFiber Pro provides double ended fiber optic inspection capability through the use of 2 Versiv Main units. One unit acts as the normal CertiFiber Pro main and the 2nd unit functions as a Remote unit. Using a Main unit as a Remote provides a touchscreen interface at the remote end giving you the ability to visually inspect fiber endfaces!

Double Ended Fiber Optic Endface Certifier

CertiFiber Pro's double ended fiber optic inspection capability allows you to inspect and certify fiber optic connector end-faces at both ends of your fiber link in less than a second so you can get your job done the first time. This double ended fiber optic inspection capability provides automated PASS/FAIL certification take the guess work out of fiber inspection so anyone can be a fiber expert.

Create, Manage and Select Projects

As part of the Versiv family, the CertiFiber Pro OLTS incorporates ProjX to ease job set-up, minimize test limit errors and better manage multiple projects. Project managers and technicians can create new projects for different jobs, locations or customers and or easily define project requirements for each job ahead of time – including all tests parameters and cable IDs – then keep track of job progress. All project detail information is stored in LinkWare for easy transfer to other Versiv cabling certification testers.

The ProjX management system allows project specifications to be loaded and saved into the tester ahead of time. As the tester moves from job to job, the project list is easily accessible and users can quickly see detail data such as percentage of links tested, percentage to completion and percentage of results exported.

Fiber Types and Testing Attributes

Set-up or view test limits, fiber types,and testing attributes in the field or the office.

Projects Details

View multiple projects in the office
or the field.

Arrow
View Specific Project Details

Touch a project icon to see project specific detail.

Dynamic Project and User Profile Management

CertiFiber Pro increases efficiency by allowing field technicians access to project based settings entered at the time of set-up. This minimizes set-up errors or lost files when switching from one job to another or utilizing multiple testers on a single job more. Setting limits and establishing cable ID sets is easy with the Taptive user interface. And once the technicians start testing, the progress of each project is easily monitored.

ProjX Management System specific benefits are: Real time status to completion on each job 0-100%, giving the operator the “Fix Later” option to isolate any test requiring a second look and helps to assure nothing is overlooked. The “Fix Later” selection creates a punch list or automatic “to do” list for correcting any workmanship issues.

Managing the testing of multiple jobs with multiple teams, testers, and requirements is time consuming and can be hard to manage. Increasingly larger jobs make project organization more important than ever. The new ProjX management system on the CertiFiber Pro assigns a name for all job specifics. This eliminates the need to ever have to re-enter test limits or other job details after starting a project or returning to it after a different job. This minimizes set-up errors or lost files when switching from one job to another or utilizing multiple testers on a single job, enabling project managers and crew leaders to be more efficient.

Selecting Reference Method

The key to good test results is tester set-up. The CertiFiber Pro refers to the settings already chosen for the project and guides the technician through setting a reference – taking the guesswork out of getting ready to test in the field.

Set Reference

Setting a reference no longer has to be a challenge. The CertiFiber Pro OLTS has set a reference wizard function to guide the technician through setting a reference and checking test reference cords. The animated set-up helps reduce optical loss testing set-up errors that often result in confusing negative loss readings.

Animated set-up guide

OLTS Tier 1 (Basic)
OTDR Tier 2 (extended)

LinkWare Live

LinkWare Live is a Software as a Service from Fluke Networks for cabling professionals managing multiple projects that quickly, easily and affordably provides unmatched job visibility and superior project control from anywhere at anytime

LinkWare Live provides increased productivity by no longer needing to recall testers from the field just to download test results. Just upload the results from the tester to LinkWare Live from the jobsite so you can finish sooner, get home sooner and get paid faster. LinkWare Live reduces reporting time by automatically consolidating all results into correct job, and cuts rework by reducing the likelihood of losing test results when testers or memory cards are lost, stolen or erased. LinkWare Live provides instant access to results for faster troubleshooting, real time visibility into project status from any location and fully integrates with LinkWare PC for fast reporting.

LinkWare Live also reduces errors by allowing Project Managers to set testers up remotely through smart phones, tablets, or PC's. And if someone changes that setup, LinkWare Live will let you know.

LinkWare Live Software Screen

CertiFiber Pro connects to the LinkWare Live service through Wi-Fi or wired connections to provide remote setup, results uploading, and testing status information.

Software de gerenciamento LinkWare PC

Com o software de gerenciamento LinkWare PC, os usuários do CertiFiber Pro podem acessar facilmente os dados do sistema de gerenciamento ProjX, gerar relatórios e atualizar o software em seus testadores. Os gerentes de projeto possuem plenas capacidades para monitorar o fluxo de trabalho e consolidar os resultados do teste.

O LinkWare PC fornece relatórios estatísticos automáticos. Este aplicativo lhe apresenta mais do que um relatório por página, ele permite que você visualize sua estrutura de cabeamento inteira em um resumo. Ele analisa e transforma resultados de teste em gráficos para revelar o desempenho de sua planta de cabeamento. O relatório ainda resume sua infraestrutura de cabeamento inteira em um formato compacto gráfico, então fica fácil de verificar margens e anomalias pontuais. Versões anteriores do LinkWare PC são compatíveis com as novas versões, então você pode ficar atualizado e integrar testes de diferentes testadores em um único relatório de testes.

Combine OLTS Nível 1 (básico), OTDR Nível 2 (estendido) e imagens e resultados de certificação da inspeção de fibra em um único relatório enquanto permite o gerenciamento de vários trabalhos simultaneamente. Os usuários podem dar o toque final adicionando o logo de suas empresas ao relatório antes de oferecê-lo a seus clientes para aceitação do sistema. Tenha em seu negócio ferramentas simples. Não importa qual testador de certificação de cabos da Fluke Networks você usa, o LinkWare PC fornece relatórios para todos.

Relatório do LinkWare

Relatório LinkWare com Encircled Flux

Relatório do LinkWare com testes de fluxo fechado e cabos de referência de teste

Certificação de cabeamento com LinkWare

Especificações do módulo de conjunto de teste de perda óptica CertiFiber Pro

Especificações do medidor de potência
Conector de entrada Adaptador de conector intercambiável (LC padrão, SC, ST e FC opcional)
Tipo de detector InGaAs
Comprimento da onda 850 nm, 1300 nm, 1310 nm, 1550 nm
Faixa de Medição de Potência 0 dBm a -65 dBm (850 nm) 0 dBm a -70 dBm (todos os outros comprimentos de onda)
Incerteza da medição de potência1,2 < +/- 5% +/- 32 pW
Linearidade da medição3 < ± 0,1 dB
Período de recalibração 1 ano
Wi-Fi integrado Atende a IEEE 802.11a/b/g/n; banda dupla (2,4 GHz e 5 GHz)

1. +/- 100 pW a 850 nm
2. Nas seguintes condições: Nível de potência100 μW (-10 dBm), onda contínua (CW) para potência absoluta a 850 nm e 1310 nm. Feixe divergente, NA = 0,20 para 50/125 μm e NA = 0,14
para 9/125 μm. Temperatura ambiente 23° ± 1°C. Conector SC/UPC com ponteira de cerâmica. Após aquecimento de 5 minutos. Rastreável de acordo com o NIST.
3. -3 dBm a -55 dBm à 850 nm e 1310 nm. Temperatura ambiente 23° ± 1°C. Após aquecimento de 5 minutos.

Especificações de perda/comprimento
Especificação Módulos Multimodo do CertiFiber Pro Módulos Monomodo do CertiFiber Pro
Velocidades de teste (exclui
os tempos de referência)

Modo Remoto Inteligente: < 3 segundos (2 comprimentos de onda, direção única, detecção automática de comprimento de onda)

Modo Fonte Remota: ≤ 2 segundos (2 comprimentos de onda, direção única, detecção automática de comprimento de onda)

Modo Loopback: ≤ 2 segundos (2 comprimentos de onda, direção única, detecção automática de comprimento de onda)

Conectores de Entrada/Saída Adaptador de conector intercambiável (LC padrão, SC, ST e FC opcional)
Condição de lançamento1,2 Compatível com Encircled Flux de acordo com TIA-526-14-B, ISO/IEC 14763-3, e IEC 61280-4-1
Tipos de fibra testados 50/125 µm ou 62,5/125 µm Monomodo
Tipo de fonte e comprimento de onda Fonte de LED 850 nm ± 30 nm 1300 nm ± 20 nm Laser diodo Fabry-Perot 1310 nm ± 20 nm 1550 nm ± 30 nm
Medição de comprimento máximo 12 km 130 km
Precisão da medição do comprimento: ± 1,5 m mais ± 1% de comprimento
Potência de Saída (Nominal) ≥ -24 dBm com EF-TRC ≥ -4 dBm
Estabilidade da potência de saída3 ± 0,05 dB durante 8 horas ± 0,03 dB durante 15 minutes ± 0,1 dB durante 8 horas ± 0,08 dB durante
15 minutes

1. Na saída do EF-TRC
2. Podem ocorrer variações entre os equipamentos de medição de EF, mas pode-se esperar conformidade com EF com um fator de confiança de 95%
3. Relativo ao nível de potência após 15 minutos de aquecimento - a temperatura constante

Especificações perda/comprimento (contínua)
Comprimentos de onda de origem 850 nm, 1300 nm, 1310 nm, 1550 nm
Faixa de Medição de Potência 0 dBm a -65 dBm (850 nm) 0 dBm a -70 dBm (todos os outros comprimentos de onda)
Incerteza da medição de potência1, 2 < +/- 5% +/- 32 pW
Linearidade da medição3 < ± 0,1 dB
Período de recalibração 1 ano

1. +/- 100 pW a 850 nm
2. Nas seguintes condições: Nível de potência100 μW (-10 dBm), onda contínua (CW) para potência absoluta a 850 nm e 1310 nm. Feixe divergente, NA = 0,20 para 50/125 μm e NA = 0,14
para 9/125 μm. Temperatura ambiente 23° ± 1°C. Conector SC/UPC com ponteira de cerâmica. Após aquecimento de 5 minutos. Rastreável de acordo com o NIST.
3. -3 dBm a -55 dBm à 850 nm e 1310 nm. Temperatura ambiente 23° ± 1 °C após aquecimento de 5 minutos.

Especificações selecionadas

Localizador visual de falhas (VFL)
Título Requisitos
Potência de saída > -5 dBm
<0 dBm
fibra monomodo SMF-28
Onda contínua
conector SC/UPC
Comprimento de onda de operação 650 nm nominal
Modo de saída Onda contínua
Modalidade pulsada (2 Hertz a 3 Hertz da frequência do piscamento)
Adaptador do conector 2,5 mm universal
Segurança do laser CDRH da Classe II
Faixa de temperatura operacional
Especificações ambientais
Título Requisitos
Temperatura de operação 0 °F a 113° F (-18° C a 45° C)
Temperatura de Armazenamento -22°F a 140°F (-30°C a +60°C)
Umidade relativa de operação (% UR sem condensação)
0% a 90%, 32°F a 95°F (0°C a 35°C)
0% a 70%, 95°F a 113°F (35°C a 45°C)
Vibração Aleatória, 2 g, 5 Hz a 500 Hz
Impacto Teste de queda de 1m com e sem módulo e adaptadores
Segurança
CSA C22.2 no. 1010,1: 1992
EN 61010-1 1a edição + emendas 1, 2
Grau de poluição 2
Altitude Operação: 4.000 m; armazenamento: 12.000 m
EMC EN 61326–1

Informações para Pedidos

Modelos sem fio CertiFiber Pro
Modelo Descrição
CFP2-100-QI Kit CertiFiber Pro Quad OLTS V2 com inspeção de extremidade dupla e Wi-Fi
CFP2-100-QI/GLD Kit CertiFiber Pro Quad OLTS V2 com inspeção de extremidade dupla, Wi-Fi e 1 ano de Gold Support
OFP2-CFP-QI Kit OptiFiber Pro, CertiFiber Pro Quad V2 com inspeção e Wi-Fi
CFP2-100-Q Kit CertiFiber Pro Quad OLTS V2 com Wi-Fi
CFP2-100-Q/GLD Kit CertiFiber Pro Quad OLTS V2 com Wi-Fi e GOLD SUPPORT de 1 ano
CFP2-100-M CertiFiber Pro Multimodo OLTS V2 com WI-FI
CFP2-100-S CertiFiber Pro Monomodo OLTS V2 com WI-FI
CFP2-Q-ADD-R Kit adicional CertiFiber Pro com Quad OLTS com unidade Remota V2 (incompatível com o mainframe Versiv original)
Modelos sem wi-fi CertiFiber Pro
Modelo Descrição
CFP2-100-Q-NW Kit CertiFiber Pro Quad OLTS V2
CFP2-100-M-NW Kit CertiFiber Pro Multimodo OLTS V2
CFP2-100-S-NW Kit CertiFiber Pro Monomodo OLTS V2
Acessórios Descrição
CFP-MM-ADD Kit adicional de Módulos Multimodo do CertiFiber Pro
CFP-SM-ADD Kit adicional de Módulos Monomodo do CertiFiber Pro
CFP-Q-ADD Kit adicional de Certifiber Pro Quad (módulos e TRCs SC/LC)
CFP2-Q-ADD-R Kit adicional de Certifiber Pro Quad com unidade Remota V2 (módulos e TRCs SC/LC)
OFP-Q-ADD Kit adicional Optifiber Pro Quad (módulo e cabos de lançamento SC/LC)
SRC-9-SCLC-KIT Kit de cabos de referência de teste monomodo (2 m) para teste de fibras com terminação LC (2 SC/LC, 2 LC/LC)
SRC-9-SCSC-KIT Kit de cabos de referência de teste monomodo (2 m) para teste de fibras com terminação SC (4 SC/SC)
MRC-50EFC-SCLCKIT Kit de cabos de referência para teste compatível com Encircled Flux (EF) multimodo para teste de fibras terminadas em LC de 50um (2 SC/LC, 2 LC/LC)
MRC-50EFC-SCSCKIT Kit de cabos de referência para teste compatível com Encircled Flux (EF) multimodo para teste de fibras terminadas em LC de 62,5um (2 SC/LC, 2 LC/LC)
MRC-625EFC-SCSCKIT Kit de cabos de referência para teste compatível com Encircled Flux (EF) multimodo para teste de fibras terminadas em SC de 62,5um (4 SC/SC)
FI-1000-KIT A Sonda em Vídeo de Inspeção de Fibra USB para produtos Versiv além do conjunto ponta (anteparo LC, FC/SC, 1,25 e pontas universais de 2,5 milímetros em uma caixa).
Modelos com Gold Support CertiFiber
Modelo Descrição
GLD-CFP-100-QI
GLD3-CFP-100-QI
GLD-CFP-100-Q
GLD3-CFP-100-Q
GLD-CFP-100-M
GLD3-CFP-100-M
GLD-CFP-100-S
GLD3-CFP-100-S
GLD-CFP-Q-ADD-R

Para uma lista completa de modelos e acessórios CertifFiber Pro, visite www.flukenetworks.com/certifiberpro

Configure o CertiFiber Pro de acordo com seus requisitos exatos visitando www.flukenetworks.com/versiv-config.

 
 
Powered By OneLink