Test times - DSX CableAnalyzer

The biggest time savings come from setting the DSX CableAnalyzer up in advance using ProjX™, which prevents the technician from testing to the incorrect test limit etc.

F/UTP and S/FTP links take ≈ 0,8 seconds longer to test than U/UTP links due to the addition of a unique shield integrity test.

Notas:

  • The first Autotest after powering up will take an additional 1,5 to 2,3 seconds as it retrieves the calibration constants from the remote unit. 
  • Autotest test times stated are ± 0,1 seconds


     
  • Where ​(+All) adds Resistance UnbalanceTCLELTCTLCDNEXT and CMRL to the test