TCL (Transverse Conversion Loss) - DSX CableAnalyzer | Fluke Networks

Base de conhecimento

KB Home   >  Teste de cobre   >  DSX CableAnalyzer™ Series

TCL (Transverse Conversion Loss) - DSX CableAnalyzer

TCL is one of two balance measurements found in ANSI/TIA-568-C.2, ANSI/TIA-1005 and ISO/IEC 11801 Edition 2,2 2011-06. The other is ELTCTL.
 
The measurement is made by injecting a differential mode signal (DM) into a twisted pair, then measuring the common mode signal (CM) returned on that same twisted pair. The smaller the CM signal returned, the better the TCL measurement (balance).
 
            

If it looks similar to a Return Loss measurement, you're right. Except a Return Loss measurement is made by injecting a DM signal into the pair and measuring the DM signal returned. Here we are measuring the CM signal returned which is TCL.

Field test requirements for ANSI/TIA-568-C.2 are deferred to ANSI/TIA-1152. At this time, TCL is not a field test requirement because until the DSX CableAnalyzer came along, no field test equipment vendor could perform a TCL field test. It is anticipated that other test equipment vendors will eventually offer TCL field measurements too. Field testers are normally capable of DM measurements only - the DSX CableAnalyzer is capable of both DM and CM measurements, hence its ability to measure TCL and ELTCTL.

If you wish to add ELTCTL and TCL to your standard Category 5e, 6, 6A or Class D, E or EA test, select your ISO or TIA folder in DSX and look for a test limit with a suffix of (+All):
 
            Test Limit for all TIA Categories           Test Limit for all ISO Categories

This will add ≈ 6,6 seconds to your AUTOTEST time.

The suffix of (+All) indicates a standard ANSI/TIA or ISO/IEC test with the addition of ELTCTL, TCLResistance Unbalance within a pairResistance Unbalance between pairsCMRL and CDNEXT measurements.
 
In the example below from a DSX-5000 CableAnalyzer, a Category 6A Channel was tested. With a margin of 5,4 dB (6 dB is a factor of 2), you can feel confident that this link will perform well, even in a noisy environment.
 
        DSX CableAnalyzer Balance Measurement Screen


Why is balance important?
Ethernet transmits a balanced signal. The idea is that any noise injected into the cable is cancelled out, assuming the link has good balance. It also indicates how much signal the link emits.

            Good Balanced Link
 
 
If the link has poor balance, the noise injected into the cable becomes part of the signal. The imbalance in the link causes the injected voltage on the pairs to be unequal.
  
            Poor Balanced Link


This has the potential of creating errors on the network, resulting in re-transmission of signals and slower network performance. This can be particularly problematic in Industrial Ethernet applications where latency is critical. In a data center where it is also particularly noisy and where transaction times are measured in mS, re-transmitting a signal could result in a delayed transaction.