05-11-2015

Testing Wide Band Multimode Fiber - WBMMF

Multimode fiber (MMF) dominates in local area networks and data centers. Electro-optic converters (e.g. transceivers) used for transmitting and receiving data are less expensive than those used for transmitting over single-mode fiber. Network capacity has increased over the years through the use of parallel transmission – using multiple fibers and multiple transceivers. As the need for capacity continues to increase, the use of multiple fibers and multiple transceivers needed for parallel transmission may increase network cost.

28-10-2015

Golden Rule of Fiber Inspection - Clean and Inspect Again

Contaminated connections remain the number one cause of fiber related problems and test failures in data centers, campus and other enterprise or telecom networking environments.

22-10-2015

Standard Update: 25GBASE-T Joins the Party!

Since the development of 40GBASE-T (IEEE 802.3bq) began a few years ago, most of us believed that the next Ethernet data center speed for twisted-pair copper cabling beyond 10 Gb/s would be 40 Gb/s.

12-10-2015

The Best Just Got Better—at Both Ends

How long are the fiber links you need to test? Is it a short 50-meter multimode data center link, a longer 550-meter backbone, or maybe even a 130-kilometer singlemode link?

With contaminated connections remaining the number one cause of insertion loss and back reflection that inhibits optical transmission and causes havoc with expensive transceivers, it’s vital that fiber end-faces at both ends of a link are visually inspected.

02-10-2015

Help! My Copper Cabling Link Failed

You’ve just finished a copper cabling installation for a customer, your DSX-5000 CableAnalyzer is properly configured and you’re ready to start testing. With a press of the “TEST” button, you’re off and running.

Link after link, the tester displays a “Pass” and you’re feeling really good about the quality workmanship of your installation.

30-9-2015

Certification vs. Qualification: A Closer Look

cer·ti·fy \ˈsər-tə-ˌfī\ verb 1: to attest authoritatively  2: to officially recognize someone or something as possessing certain qualifications or meeting certain standards

qual·i·fy \ˈkwä-lə-ˌfī\ verb 1: to have the necessary skill or knowledge to do a particular job or activity  2: to have the qualifications to do something

28-9-2015

Fluke Networks homenageada pelo 2015 Programa de prêmios para inovadores da Cabling Installation & Maintenance

Last week at the opening of the BICSI Conference in Las Vegas, the editors of Cabling Business Magazine announced that Versiv and LinkWare Live have each won the Cabling Installation and Maintenance Innovator’s Award. These awards recognize the most innovative projects and products in the structured cabling industry. A Comissão Julgadora consistia de especificadores, designers, integradores e gestores de sistemas de cabeamento e comunicações com vasta experiência profissional.

15-9-2015

What is Your Loss Measurement Uncertainty?

Testing structured fiber cabling to international standards such as ISO/IEC 14763-3 has been defined. In the last few years, the question of loss (attenuation) measurement uncertainty has been raised. Since 14763-3 specifies test limits, the user of the standard may need to know the amount of uncertainty in the measurement. Experts from IEC, well-versed in fiber metrology and uncertainty calculations, were requested to provide simplified guidelines, a table of sorts, that a user such as an installer might find useful.

20-8-2015

Tier 1 Testing using an OTDR on Installed Fiber Cabling?

The Telecommunications Industry Association (TIA) is committed, by formal consensus, to develop standards for the benefit of industry and is represented by hundreds of companies. While participating companies cooperate to develop standards, each have their commercial business interests to protect. Sometimes, these companies over-reach to meet their business goals. Fortunately, the TIA voting and balloting process works well as a means to check and balance sometimes rogue proposals.

17-8-2015

Testing Installed Fiber Cabling Terminated with MPO Connectors

Several published standards describe how to perform attenuation measurements on installed fiber optic cabling. However, no standard exists that provides guidance for testing installed fiber optic cabling terminated with MPO connectors. Currently, a technical report (TR) is being drafted that provides such testing guidance.