Renaming an Autotest already saved in the DTX CableAnalyzer

 

You accidently saved the Autotest with the wrong Cable ID! It is possible to rename that Autotest once you import it into LinkWare, but you can also rename the Autotest in the DTX CableAnalyzer.

 

  • Rotate the dial to SPECIAL FUNCTIONS
  • Highlight View/Delete Results
  • Press ENTER
  • Highlight the Autotest you wish to rename
  • Press ENTER
  • Press SAVE
  • Enter your new Cable ID
  • Press SAVE

You will need Version 2,77 Software on your DTX CableAnalyzer to do this.

Autor: Fluke Networks

Data de criação: 24-2-2014

Última alteração: 24-2-2014

 
 
 
 