Test Reference Cord specifications
Fluke Networks offers test cords with reference grade connectors in accordance with standards such as ANSI/TIA-526-14-C and ISO/IEC 14763-3. The requirements of these standards for loss at the connector are 0,10 dB for multimode and 0,20 dB for singlemode.
Our test reference cords are made to the following specifications:
Multimode 50/125 µm
- Cable: OFS, LaserWave 300 (OM3), ±1,0 μm core diameter
- Jacket color: Aqua
- Insertion Loss (reference grade)1 0,07 dB maximum against the MTC <0,1 dB random mating
- Return Loss: máximo de 40 dB
- Radius of Curvature per GR-326: 7 mm to 25 mm
- Apex Offset per GR-326: 0 to 50 µm
- Fiber Height (spherical fit) per GR-326: -100 nm to + 100 nm
- Angular Offset per GR-326: -0,3 degrees to +0,3 degrees
- Fiber Roughness (Rq) per GR-326: 0 to 50 nm
- Ferrule Roughness (Rq) per GR-326: 0 to 50 nm
Multimode 62,5/125 µm
- Cable: OFS, Laser Optimized 62,5 XL ±1,0 μm core diameter
- Jacket color: Orange
- Insertion Loss (reference grade)1 0,07 dB maximum against the MTC <0,1 dB random mating
- Return Loss: máximo de 40 dB
- Radius of Curvature per GR-326: 7 mm to 25 mm
- Apex Offset per GR-326: 0 to 50 µm
- Fiber Height (spherical fit) per GR-326: -100 nm to + 100 nm
- Angular Offset per GR-326: -0,3 degrees to +0,3 degrees
- Fiber Roughness (Rq) per GR-326: 0 to 50 nm
- Ferrule Roughness (Rq) per GR-326: 0 to 50 nm
Singlemode 9/125 µm (UPC)
- Cable: Corning, SMF 28e+
- Jacket color: Yellow
- Insertion Loss (reference grade)2 0,17 dB maximum against the MTC <0,2 dB random mating
- Return Loss: máximo de 50 dB
- Radius of Curvature per GR-326: 7 mm to 25 mm
- Apex Offset per GR-326: 0 to 50 µm
- Fiber Height (spherical fit) per GR-326: -100 nm to + 100 nm
- Angular Offset per GR-326: -0,3 degrees to +0,3 degrees
- Fiber Roughness (Rq) per GR-326: 0 to 50 nm
- Ferrule Roughness (Rq) per GR-326: 0 to 50 nm
Singlemode 9/125 µm (APC)
- Cable: Corning, SMF 28e+
- Jacket color: Yellow
- Step or conical endface: Step
- Insertion Loss (reference grade) 0,15 dB maximum3
- Return Loss: máximo de 65 dB
- Radius of Curvature per GR-326: 5 mm to 12 mm
- Apex Offset per GR-326: 0 to 50 µm
- Fiber Height (spherical fit) per GR-326: -100 nm to + 100 nm
- Angular Offset per GR-326: 7,5 degrees to 8,5 degrees
- Fiber Roughness (Rq) per GR-326: 0 to 50 nm
- Ferrule Roughness (Rq) per GR-326: 0 to 50 nm
1Maximum insertion loss for 2,5 mm ferrules is based on interoperability and 2 standard deviations. For maximum insertion loss, 95% should meet the specification. During testing of the insertion loss using a master test cord (MTC), the maximum allowed test is to be less than 0,07 dB to achieve interoperability
2Maximum insertion loss for 2,5 mm ferrules is based on interoperability and 2 standard deviations. For maximum insertion loss, 95% should meet the specification. During testing of the insertion loss using a master test cord, the maximum allowed test should be less than 0,17 dB to achieve interoperability
3Except for E2000 which is 0,40 dB maximum.