Excessive "SPR" Reclassed to Defective (SHT)

Solução: Pair Gain type pairs will often times appears with test results of Short or with high resistance fault if the Leakage test option is turned on. Below is a brief description of what a Pair Gain circuit looks like.
 
Thus on Pair Gain circuits, be careful in assigning the proper status codes. If you get unusual footage readings or consistent short readings such as 0.010Kr:R on several pairs in a row, this could be an indication that it is a pair gain circuit. For Pair Gain circuit, do NOT status these pairs to defective. Leave them as spare pairs once you have confirmed that they are pair gain pairs.

 