OVR - PentaScanner | Fluke Networks

Base de conhecimento

KB Home   >  Teste de cobre   >  PentaScanner

OVR - PentaScanner

The last PentaScanner left the factory back on 31 de março de 2004. We regret to say support ended 31 de março de 2008. It's replaced by the Versiv familly of testers
   
Perda de retorno
If (Over range) is displayed, the Return Loss is less than 20 dB.
 
Impedância
If (Over range) is displayed, the Impedance is greater than 200 ohms, the cable is less than 40 feet long, or the cable/pair is not connected.
 
Impulse Noise
Count indicates the cumulative count of impulses detected since the start of the measurement. When the Count exceeds 65535, (Over Range) is displayed. In an Over Range condition, the last average CPS (Counts Per Second) recorded is displayed.
 
Peak-to-Peak Noise
If the Peak-to-Peak noise level exceeds 3.000 mV, (Over Range) is displayed.
 
Resistência de Loop DC
If (Over Range) is displayed, the Loop Resistance is greater than 10K ohms.
 
Capacitance
If (Over Range) is displayed, the Capacitance is greater than can be measured or the cable is properly connected.

Autor: Fluke Networks

Data de criação: 26-2-2014

Última alteração: 26-2-2014

 
 
 
 
Powered By OneLink