If you get the following message;
  
            

"Check fiber connections. The measured power levels are outside the range expected for setting a reference.", then your Test Reference Cords are either bad/dirty or the ports on the DTX-xFM modules are dirty/bad. A simple inspection using the FiberInspector™ Mini.

This warning will appear when the reference values fall outside of the following ranges:

Smart Remote Mode
            DTX-MFM: -17,5 dBm a -27,0 dBm
            DTX-GFM: -4,5 dBm a -10,0 dBm
            DTX-SFM: -4,5 dBm a -10,0 dBm

In this example, if we pressed F2 OK you would have been presented with:
 
            
 
Where we clearly see that the measured power has dropped outside of the expected range for this DTX-MFM.