Create an Autotest for Coaxial Cable (PentaScanner) | Fluke Networks

Base de conhecimento

KB Home   >  Teste de cobre   >  PentaScanner

Create an Autotest for Coaxial Cable (PentaScanner)

The last PentaScanner left the factory back on March 31, 2004. We regret to say support ended March 31, 2008. It's replaced by the Versiv familly of testers
 
NOTE: You cannot run an AUTOTEST or SAVE the test results.  
  
 
At the Ready! Screen, press the Extended Functions button.
 

 
 
Select 2. Setup Autotest.
 

 
 
Highlight the CAT5 Channel Autotest.
 

 
 
Press F2 (Edit). Select 3. Tests To Run; unselect NEXT and select Impedance, Loop Resistance and Capacitance.
 

 
 
Press F1 (Save)
 
Select 2. Pairs.
 

 
Using the arrow keys and the F2 (Unsel/Select) key, place an x in the boxes so that the 3-6 boxes are the only ones with an x in both boxes.
 
Press F1 (Save)
 
Select 4. Limits
 

 
 
Select 6. Impedance
 

 
 
Change 80 to 135
 
Down arrow to the Maximum field
 
Change 125 to 165
 
Press F1 (Save)
 
Press Escape
 
Press Escape
 
Press F1 (default). You will be defaulting to the *CAT5 Channel Autotest for the PentaScanner. The asterisk indicates this is a user-defined Autotest.
 

 
 
If the cable you are testing is near 328 feet, you may need to change the maximum Length limit from 328 to 361 feet. Other limits such as Loop Resistance and Capacitance may need to be changed in proportion to the increase in Length limit if these tests are failing marginally.
 
You are now ready to press MEASURE CABLE PERFORMANCE. You cannot run an AUTOTEST or SAVE the test result.

Author: Adrian Young

Creation Date: 2014-02-26

Last Modified: 2014-02-26

 
 
 
 