OptiFiber- Release notes- Knowledge Base

Base de conhecimento

KB Home   >  Teste de fibra   >  OptiFiber®

Release notes - OptiFiber

Need help updating your OptiFiber? Click here for instructions.

1. Cable / Spec Database Change

  • Optical loss method name change to harmonize with all standards
    • Changed Method A to 1 Jumper
    • Changed Method B to 2 Jumper
    • Changed Method C to 3 Jumper
  • OTDR General Fiber Limit
    • Overall Loss and Length limits removed so users can test beyond 5,000 m on singlemode without seeing a FAIL
  • Optical Loss General Fiber Optic limit changed (Only used as a place holder to create custom fixed loss limits)
    • 850 nm: 8.5 dB and 2,000 m
    • 1300 nm: 4.5 dB and 2,000 m
    • 1310 nm: 6.5 dB and 5,000 m
    • 1550 nm: 6.5 dB and 5,000 m
  • Added JIS X5150 fiber specification
  • Added Russian fiber specification
  • Added 10GBASE-LRM
  • Added the following cables
    • Berk-Tek
    • Kerpen/Leoni
    • InfraPlus
    • Remee Products Corp.
  • Updated the following cables
    • CommScope
    • SYSTIMAX
    • Belden
  • OM1 fiber changed from 160 MHz.km to 200 MHz.km to harmonized with ANSI/TIA-568-C.3
  • Added OS2 fiber
  • Added new limits
    • ISO/IEC 11801-2010 2-Pigtl
    • ISO/IEC 11801-2010 2-Conn
    • ISO/IEC 14763-3 2-Pigtl
    • ISO/IEC 14763-3 2-Conn
    • ANSI/TIA-568-C
    • General Fiber RL -35dB
    • General Fiber RL -40dB
  • Name change only from 10GBASE-S to 10GBASE-SR
  • Name change only from ISO11801 Fiber Optic Link to ISO11801 Fiber Optic Link (2002)

 

2. Bug Fixes

  • Fix 57723: OTDR partially issue at 850 nm
  • Fix 56093: Help screen for referencing SC links incorrect for 1 Jumper (Method B)
  • Fix 51450: OTDR Port on FaultMap for multimode modules too sensitive

Author: Adrian Young

Creation Date: 2014-04-03

Last Modified: 2014-04-03

 
 
 
 
Powered By OneLink