If you see the Red LED permanently on and the Green LED flashing as shown below, then the upgrade process has halted the OMNIScanner needs a little help.

  • Keep the OMNIScanner and the OMNIRemote connected together using the Link adapter and Channel adapter.
  • Remove the battery and AC power from the OMNIRemote.
  • Make sure the OMNIScanner is ON.
  • Press and hold the On/Off button on the OMNIRemote.
  • Keep holding the power button and attach the AC power to the OMNIRemote.
  • Continue to hold the On/Off button on the OMNIRemote and start the OMNIScanner Reflash on your PC again.
  • When the Reflash is finished with the OMNIScanner, you will get a message that says Please attach Remote for Reflash - If Reflash is not started automatically press F1
  • Press F1 on the OMNIScanner.
  • When all (or most) of the LED's come on the OMNIRemote, release the On/Off button.
  • The Status and Pass LED's should begin blinking back and forth.
  • Reflash will be completed.