Check fiber connections. The measured power levels are........ DTX-MFM2

If you get the following message;
  
             DTX MFM2 Warning Message

"Check fiber connections. The measured power levels are outside the range expected for setting a reference.", then your Test Reference Cords are either bad/dirty or the ports on the DTX-xFM2 modules are dirty/bad. A simple inspection using the FiberInspector™ Mini should reveal if the end faces need cleaning or are damaged and in need of replacement.
 
This warning will appear when the reference values fall outside of the following ranges:
 
Smart Remote Mode
            DTX-MFM2: -17.5 dBm to -27.0 dBm
 
In this example, if we pressed F2 OK you would have been presented with:
 
            Reference Result Screen
 
Where we clearly see that the measured power has dropped outside of the expected range for this DTX-MFM2.

Author: Adrian Young

Creation Date: 2014-03-27

Last Modified: 2014-03-27

 
 
 
 